Supply voltage |
2.0–3.8 VDC (AA alkaline or lithium batteries) |
Current consumption |
0.2 µA (sleep mode), 0.7 µA (RTC sleep), 570 µA (MCU idle), 2.5 mA (MCU active), 5.5 mA (radio RX mode), 22.6 mA (radio TX mode) |
Operating temperature range (board circuitry and battery) |
-18°C to 55°C(0°F to 130°F ) using alkaline, -40°C to +85°C (-40°F to +185°F) using lithium |
Optimal Battery Temperature
Range (AA) |
+10°C to +50°C (+50°F to +122°F) |
Integrated memory |
Up to 3200 sensor messages |
Wireless range720 |
+ ft non-line-of-sight |
Security |
Encrypt-RF® (256-bit key exchange and AES-128 CTR) |
Weight |
87 g |
Certifications |
900 MHz product; FCC ID: ZTL-G2SC1 and IC: 9794A-G2SC1.868 and 433 MHz product tested and found to comply with: EN300 220-2 V3.1.1 (2017-02), EN 300 220-2 V3.1.1 (2017-02) and EN 60950 |
Sensor Specification |
Temperature Measurement Specifications |
Range: -40°C to +125°C (-40°F to +257°F) |
Accuracy: +/- 1° C (1.8° F) |
User-calibrated accuracy: ± 0.25° C (+/- 0.45° F) |
Resolution: 0.1° C (0.1° F) |
Response time: 15 sec max* |
Units: C or F (User configurable on sensor and in portal) |
Lead Specifications |
Probe Material: 304 stainless steel. |
Probe Dimensions: 5 mm dia. x 35 mm |
Lead Length: 3 ft or 10 ft (Contact distributorfor custom length options) |
Thermistor based temperature element |
Shielded cable and probe |
Display Specifications |
Operating temperature range: -10°C to 60°C (14°F to 140°F) |
Storage temperature range: -20°C to 70°C (-4°F to 158°F) |
Symbols: 4 digits, 3 decimals, C/F, Low Battery, Signal Strength, Minus symbol |
Viewing Area: 14.0 mm x 26.0 mm |
Digit Size: 8.5 mm x 4.5 mm |
Current consumption: ~260 uA |
Sensor Data |
Temperature: xxx.x C or F, Signed Integer (Raw temperature data is in Celsius) |
Mode: 0 or 1, 0 = Read button not pressed, 1 = Read button pressed, Unsigned Byte |