| Supply voltage |
2.0–3.8 VDC (3.0–3.8 VDC using power supply) * |
| Current consumption |
0.2 µA (sleep mode), 0.7 µA (RTC sleep), 570 µA (MCU idle), 2.5 mA (MCU active), 5.5 mA (radio RX mode), 22.6 mA (radio TX mode) |
| Operating temperature range (board circuitry and batteries) |
-18°C to 55°C (0°F to 130°F) using alkaline |
| -40°C to 85°C (-40°F to 185°F) using lithium |
| Optimal battery temperature range (AA) |
+10°C to +50°C (+50°F to +122°F) |
| Vibration Measurement Range and Units |
Acc RMS / Acc Peak: 0 to 65.535 mm/s^2, Velocity RMS: 0 to 655 35 mm/s, Dis-placement: 0 to 655.35 mm ** |
| Vibration Resolution |
0.001 mm/s^2, 0.01 mm/s, .01 mm |
| Frequency Measurement Range |
See Frequency Measurement Range table below |
| Frequency Measurement Resolution |
0.1 Hz |
| Minimum Sensitivity Range / Resolution |
Software Configurable (0 to 2.56 g / .01 g) |
| Accelerometer g-Force Range |
Software Configurable (+/- 8 g, +/- 16 g, +/- 32 g) |
| Crest Factor Measurement Range / Resolution |
1.41 to 3.97 / .01 |
| Duty Cycle Measurement Range / Resolution |
0 to 100% / 1% |
| Temperature Measurement Range / Resolution |
-40°C to +125°C ( -40°F to +257°F ) / 0.1 C (0.1 F) |
| Sample Rates |
Software Configurable (See Frequency Measurement Range table below for available Sample Rates) |
| Window Filters |
Software Configurable (Rectangular, Hanning, Flat Top)*** |
| Integrated memory |
Up to 3200 sensor messages |
| Wireless range |
1,200+ ft non-line-of-sight |
| Security |
Encrypt-RF® (256-bit key exchange and AES-128 CTR) |
| Weight |
105 g, cube dimensions: 0.75 in. x 0.75 in. x 0.75 in. |
| Certifications |
900 MHz product; FCC ID: ZTL-G2SC1 and IC: 9794A-G2SC1. 868 and 433 MHz product tested and found to comply with: EN 300 220-2 V3.1.1 (2017-02), EN 300 220-2 V3.1.1 (2017-02) and EN 60950 |