ALTA Industrial Air Velocity Sensor

ALTA Industrial Air Velocity Sensor

Wireless Sensor air velocity measures the pressure diff between two in ports, the temp, and alt determines the speed at which the air is moving in a system.

Prisförfrågan kontakta oss

Artikelnummer MNS2-8-IN-PS-AV Kategori
Varumärke:Monnit

The ALTA industrial wireless air velocity sensor measures the pressure difference between two input ports, the temperature, and altitude determines the speed at which the air is moving in a system and transmits the measurement to iMonnit. The sensor measures the pressure difference between two ports. When viewing the sensor from the top, the right inlet port is the negative or low side pressure input. When the pressure on this port is greater than the left port the sensor produces a negative pressure reading. When the pressure is greater on the left port the sensor produces a positive pressure reading. Combined with the temperature and the altitude, the sensor determines at what rate the air is flowing in a system.

Teknisk data

ALTA Industrial Wireless Air Velocity Sensor
Supply   voltage 2.7–3.8 VDC (3.0–3.8 VDC using power supply) *
Current   consumption 0.2 µA (sleep mode), 0.7 µA (RTC sleep), 570 µA   (MCU idle), 2.5 mA (MCU active), 5.5 mA (radio RX mode), 22.6 mA (radio TX   mode)
Operating   temperature range (board circuitry and battery) -40°C to +85°C (-40°F to +185°F) **
Included battery Max temperature range -40° to +85°C (-40° to +185°F)
Capacity 1500 mAh
Optional solar feature Solar panel 5VDC/30mA (53mm x 30mm)
Charging temperature range 0° to 45°C (32° to 113°F)
Max temperature range -20° to 60°C (-4° to 140°F)
Included rechargeable battery 600 mAh/>2000 charge cycles (80% of initial capacity)
Solar efficiency Optimized for high and low-light operation ***
Pressure   range -500 Pa to 500 Pa
Allowable   overpressure 100 kPa
Rated   burst pressure 500 kPa
Max   humidity for long-term exposure 40°C dew point
Range   at 0 m Altitude Range at 5000 m Altitude Range at 8000 m Altitude 0-30m/s
0-40m/s
0-50m/s
Span   repeatability 0.5% of reading
Span   shift due to temperature variation < 0.5% of reading per 10°C
Offset   stability < 0.05 Pa/year
Calibrated   for Air, N2
Media   compatibility Air, N2, O2, non-condensing
Temperature   measurement range -40°C to 85°C (-40°F to +185°F)
Calibrated   temperature measurement range 0.1°C
Temperature   resolution 0.1°C
Temperature   accuracy +/- 2°C (-10°C to +60°C)
+/- 3°C (-40°C to +85°C)
Temperature   repeatability +/- 0.1°C
Integrated   memory Up to 3200 sensor messages
Wireless   range 1,200+ ft non-line-of-sight
Security Encrypt-RF® (256-bit key exchange and AES-128 CTR)
Weight 135 g
Enclosure   rating NEMA 1, 2, 4, 4x, 12 and 13 rated, sealed and weather proof
UL   rating UL Listed to UL508-4x specifications (File E194432)
Certifications   Industry 900 MHz product; FCC ID: ZTL-G2SC1 and IC: 9794A-G2SC1. 868 and 433 MHz   product tested and found to comply with: EN 300 220-2 V3.1.1 (2017-02), EN   300 220-2 V3.1.1 (2017-02) and EN 60950