Supply voltage |
2.7–3.8 VDC (3.0–3.8 VDC using power supply) * |
Current consumption |
0.2 µA (sleep mode), 0.7 µA (RTC sleep), 570 µA (MCU idle), 2.5 mA (MCU active), 5.5 mA (radio RX mode), 22.6 mA (radio TX mode) |
Operating temperature range (board circuitry and battery) |
-40°C to +85°C (-40°F to +185°F) ** |
Included battery |
Max temperature range |
-40° to +85°C (-40° to +185°F) |
Capacity |
1500 mAh |
Optional solar feature |
Solar panel |
5VDC/30mA (53mm x 30mm) |
Charging temperature range |
0° to 45°C (32° to 113°F) |
Max temperature range |
-20° to 60°C (-4° to 140°F) |
Included rechargeable battery |
600 mAh/>2000 charge cycles (80% of initial capacity) |
Solar efficiency |
Optimized for high and low-light operation *** |
Pressure range |
-500 Pa to 500 Pa |
Allowable overpressure |
100 kPa |
Rated burst pressure |
500 kPa |
Max humidity for long-term exposure |
40°C dew point |
Accuracy |
3% of reading +/- 0.1 Pa |
Span repeatability |
0.5% of reading |
Span shift due to temperature variation |
< 0.5% of reading per 10°C |
Offset stability |
< 0.05 Pa/year |
Calibrated for |
Air, N2 |
Media compatibility |
Air, N2, O2, non-condensing |
Temperature measurement range |
-40°C to 85°C (-40°F to +185°F) |
Calibrated temperature measurement range |
0.1°C |
Temperature resolution |
0.1°C |
Temperature accuracy |
+/- 2°C (-10°C to +60°C) |
+/- 3°C (-40°C to +85°C) |
Temperature repeatability |
+/- 0.1°C |
Integrated memory |
Up to 3200 sensor messages |
Wireless range |
1,200+ ft non-line-of-sight |
Security |
Encrypt-RF® (256-bit key exchange and AES-128 CTR) |
Weight |
133 g |
Enclosure rating |
NEMA 1, 2, 4, 4x, 12 and 13 rated, sealed and weather proof |
UL rating |
UL Listed to UL508-4x specifications (File E194432) |
Certifications |
900 MHz product; FCC ID: ZTL-G2SC1 and IC: 9794A-G2SC1. 868 and 433 MHz product tested and found to comply with: EN 300 220-2 V3.1.1 (2017-02), EN 300 220-2 V3.1.1 (2017-02) and EN 60950 |